Syringe Infusion Pump

Syringe Infusion Pump - Crest

Product Details:
  • Types: Continuous Flow , Infusion Pump , High Pressure , Low Flow Rate
  • Application: Drug Delivery
  • Number of Syringes: 1.0
  • Syringe Size: 0.5 ml-10 ml, 10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml
  • Features: Digital , Programmable , Advanced Precision , Automatic , Portable
  • Minimum Order Quantity: 5 Unit

Physical Specification:
  • Product Type: Front Loading Syringe Infusion Pump
  • Pumping Mechanism: Lead screw mechanism
  • Dimension: 130mm (W) x 183mm (L) x 115mm (H)
  • Weight: 1.8 Kgs
  • Display Size & Type: 135mm x 21mm EBTN LCD Display
  • Parameters Displayed: Syringe size, Syringe Brand, Set Flow Rate Infused Volume, Occlusion level, Battery life Alarms & Indicators
  • Keypad: Capactive touch screen keypad
  • Fixation: Allows Horizontal and Vertical Mounting
  • Stackability: For interlocking of two or more units
  • Power Source: 110/220 VCA (+/- 20%), 50/60 Hz, 12VA
  • Battery: 4.8 Rechargeable NiMh Capacity minimum 4hrs @ 5ml/hr Recharging time 16 hrs
  • Operating Temp.: 05 deg to 40 deg C
  • Relative Humidity: 15 to 90% (no condensation)
  • Atmospheric Pressure: 70 to 106 Kpa

Basic Infusion Controls:
  • Syringe Capacity: 5,10,20,30,50/60 and 100 CC Auto Detection
  • Syringe Brands: Dispovan, BBraun Perfusor, BD Precise, Plastipak Romson & Sisco (Provision add 12 more brnads
  • Flow Rate: 0.1 to 1200 ml/hr (increment in step of 0.1ml/hr) Facility for Online titration
  • Purge: Upto 1200 ml/hr
  • Bolus Rate: Upto 1200 ml/hr
  • Bolus Volume: Settable (pre-set)
  • KVO / KOR: 1% of the set rate or minimum of 0.1 ml/hr
  • Mechanical Accuracy : +/-1%
  • Overall Accuracy: +/-2% (Measured Time > 1Hr, min 0.2 ml excluding syringe tolerances) (Measured as per IEC 60601-2-24)

Pressure Management:
  • Pressure Limits: Low 0.4 kg/cm2 (300 mmHg), Mid 0.8 kg/cm2 (600 mmHg), High 1.2 kg/cm2 (900 mmHg)
  • Tolerance: +/-20%
  • Anti-bolus System: Reduces significantly bolus after occlusion release (Measured as per IEC 60601-2-24)

Pre Alarms/ Alarms/ Security Features:
  • Alarms: All the alarms are expressed by means of flasahing message/symbol on the display and sound beep
  • Syringe Detection: Syringe Dislocated, Drive Disengaged, Patient Line Disconnection, Plunger Disengaged
  • Device Control: No Mains, Battery pre-alarm & Alarm, Idle Technical Malfunction
  • Infusion Control: Occlusion, Infusion End pre-alarm & Alarm KVO/KOR, Syringe Empty

Standard Accessories:
  • Unit with pole clamp, power cord & operating manual

Optional Feature:
  • Power Source: External Power 12 VDC converter (For Ambulatory supply)
  • Battery Life: Upgradable to 5 hr /10hr @ 5 ml/hr
  • Stackability: Multiple inputs AC cord for upto 8 pumps
  • Communication: RS232 Port
  • Other: Nurse call attachement

 

Quality Standard:
  • Quality Management: ISO 9001: 2008 & ISO 13485: 2003
  • Moisture Protection: IP24 as per IEC 60529 (Splash Proof)
  • Electrical Safety: Class II, Type CF
  • Conformity Standards: IEC 60601-1 & IEC 60601-2-24

Additional Information:
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Nagpur HO
  • Production Capacity: 500 / month
  • Delivery Time: 8-10 days
  • Packaging Details: Well Packed in Board Boxes.

Syringe Infusion Pump-Zion

Product Details:
  • Types: Infusion Pump
  • Application: Drug Delivery
  • Number of Syringes: 1.0
  • Syringe Size: 10 ml-60 ml
  • Features: Programmable
  • Minimum Order Quantity: 20 Number

he Plenum's Syringe Infusion Pumps Model ZION are designed to infuse the drug into the vascular system of humans. Each machine is accomplished with microprocessor control of flow rate & volume, activates alarm automatically if the infusion rate cannot be maintained or the solution runs out- all provided by a motor - driven mechanism. We are one of the leading syringe pump manufacturer in India.
Features Programmable
Syringe Size 10 ml-60 ml
Additional Information:
  • Item Code: Zion

Syringe Infusion Pump-Zeta

Product Details:
  • Dimension: 130mm (W) x 183mm (L) x 115mm (H)
  • Weight: 1.8 Kgs
  • Power Source: 110/220 VCA (+/- 20%), 50/60 Hz, 12 VA
  • Operating Temp.: 05 to 40 deg C
  • Relative Humidity: 15 O 90% (no condensation)
  • Atmospheric Pressure: 70 to 106 Kpa
  • Display Size & Type: 66mm x 33mmm Graphic LCD Monochrome
  • Minimum Order Quantity: 5 Unit

Product Specification:
  • Product Type: Front Loading Syringe Infusion Pump
  • Pumping: Mechanism: Lead Screw Mechanism
  • Parameters Displayed: Occlusion Level, Syringe Size, Syringe Brand, Drug Name, Set Flow Rate, Infused Volume, Battery Life, Alarms & Indicators
  • Keypad: Capacitive Touch Screen Keypad
  • Fixation Stackability: ALlows Horizontal & Vertical Mounting For interlocking of two or more units
  • Battery: 4.8 Rechargeable NiMh Capacity minimum 4 hrs @ 5 ml/hr Recharging time 16 hrs
  • Battery Status: Display in Bars OR hrs, and min.
  • Power Saver: Auto adjust display brightness to save battery

Basic Infusion Controls:
  • Syringe Capacity: 5, 10, 20, 30, 50/60, and 100 CC Auto Detection
  • Syringe Brands: Dispovan, BBRaun Perfusor, BD Precise, Plastipak Romson & Sisco (Provision to add 13 more brands
  • Flow Rate: 0.1 to 2000 ml/hr (increment in step of 0.1 ml/hr) Facility for Online Titration
  • Purge: Upto 2000 ml/hr
  • Priming: 3Modes: Mandatory/ Non Mandatory / Advised Rate: Upto 2000 ml/hr
  • Bolus Type: Auto & Manual
  • Bolus Rate: Upto 2000 ml/hr
  • Bolus Volume: 0.1 ml to max capacity of syringe (0.1ml incr.)
  • Bolus Indicator: Beep after infusion of every 0.5/1 ml bolus volume
  • Infusion
  •  Modes: 1. rate ml/hr (0.1ml/hr incr.)
2. Volume Limit 0.1-999.9 ml (01 ml incr.)
3. Volume/Time 0.1-999.9ml; 00h01-100h00
4. Dose Rate
# Dose Unit: mcg/min, mcg/hr, mcg/kgmin mcg/kg/hr mg/min, mg/hr mg/kr/min, mg/kg/hr
# Dilution: X mg/ml or X mg / Y ml
  • 5. Upgradable to PCA
  • Stand by: Programmable form 1 min. to 24 hrs.
  • Drug Labelling: 64 drug name with provision for user add/delete
  • KVO/KOR: Settable from 0.1 to 5 ml/hr Provision to keep it off.
  • Mechanical Accuracy: +/- 1%
  • Overall Accuracy: +/- 2% (Measured time, 1Hr, min 0.2 ml

Pressure Management:
  • Pressure Modes: Variable/3 Pre-set Levels / 10 Pre-set Levels From 100 to 900 mmHg, 50 mmHg increment
  • Pressure Limits: Low 0.4 kg/cm2 (300 mmHg)
  • Mid 0.8 kg/cm2 (600 mmHg)
  • High 1.2 kg/cm2 (900 mmHg)
  • Tolerance: +/-20%
  • DPS: Warns pressure variation
  • Pressure Monitoring: Graphic representation of the pressure limits
  • Anti-bolus System: Reduces significantly bolus after occlusion release

Pre Alarms/Alarms/Security Features:
  • Alarms: All the alarms are expressed by means of flashing message/symbol on the display and sound beep
  • Syringe Detection: Syringe Dislocated, Drive Disengaged, Patient Line Disconnection, Plunger Disengaged
  • Device Control: No Mains, Battery Pre-Alarm & Alarm, Idle, Technical Malfunction, Uncomfirmed Programming Preventive Maintenance
  • Infusion control: Occlusion Pre-alarm & Alarm, Infusion End Pre-alarm & Alarm. KVO/KOR, Syringe Empty
  • Keypad Locking: Restricsts accidental change of the infusion parameters

Standard Accessories:
  • Unit with pole clamp, Power Cord & operating manual

Optional/Upgradable Feature:
  • Power Source: External power 12 VDC converter (For ambulatory power supply)
  • Battery Life: Upgradable to 5/10 hr @ 5 ml/hr
  • Stackability: Multiple input AC cord to power upto 8 pumps
  • Communication Port: Rs 232 port
  • Data Log Event: 500 data log events in real time Expandable upto 1500 nos.
  • Other: Nurse call attachement

Quality Standard:
  • Qaulity Mangaement: ISO 9001: 2008 & ISO 13485: 2003
  • Moisture Protection: IP24 as per IEC 60529 (Splash Proof)
  • Electrical Safety: Class II, Type CF
  • Conformity Standards: IEC

Additional Information:
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: BY AIR/ON ROAD
  • Production Capacity: 500 QTY.PER MONTH
  • Delivery Time: 8-10 days
  • Packaging Details: Pack with board boxes

Syringe Infusion Pump-Zion Plus

Product Details:
  • Dimensions: 135 (H) x 272 (W) x 150 (D) mm / Weight: 2.3 Kgs./ Housing: ABS Plastic.
  • Power Source: 110/220 VAC (+/-10%), 50/60Hz, 12 VA, external power 12 VDC by a converter.
  • Display: Graphic LCD monochrome, size 66 mm x 33 mm ( 128 x 64 pixels)
  • Minimum Order Quantity: 5 Unit

INFUSION:
  • FLOW RATE RANGE: Up to 2000 ml/hr in normal mode, depending on syringe capacity (0.1 ml/hr increment)
  • SYRINGE CAPACITY: 05, 10, 20, 30/35, 50/60 ml
  • TYPE OF SYRINGE: Dispovan, BD Precise, Plastipak, BBraun Perfusor, Romoson ( Capacity to store 20 brands)
  • PRIMING: 3 modes: mandatory, not mandatory, or advised / Rate: Up to 2000 ml/h depending on syringe size
  • BOLUS: Bolus rate 1 to 2000 ml/hr (1 ml/hr Increment) . Bolus volume: 0.1 ml to max capacity of syringe (0.1 ml increment)

  • INFUSION MODES:
1] ml/h (0.1 ml/h increments)
2] Volume limit: 0.1-999.9 ml (0.1 ml increments)
3] Volume / time: 0.1-999.9 ml; 00h01- 100h00.
4] Dose rate.
# Dose units: mcg, mcg/min, mcg/hr, mcg/kg/min, mcg/kg/hr,mg, mg/min, mg/hr, mg/kg/min, mg/kg/hr, U, kU
# Dilution setting: X mg/ml or X mg / Y ml.
  • DRUG LABELLING: Display of the available drug name from the drug library. User can add or delete drug names up to 64 nos.
  • DRUG LIBRARY (Optional): In built ‘PRUDENT’ Drug library editor for setting normal infusion, bolus and loading dose parameters. Adjustment of the dilution, default infusion modes, flow rate and bolus limits in ml/h.
  • ACCURACY: Mechanical accuracy: ±1%, Overall Accuracy: ±2%,(excluding syringe tolerances)
  • END OF INFUSION: (V/T & VL) KVO: from 0.1 to 5 ml/h adjustable and storable, continuous infusion or stop.
  • PAUSE: Programmable from 1 minute to 24 hours, increments from minute to minute.
  • DATA LOG EVENT: 500 data log events in real time expandable up to 1500 nos.

PRESSURE MANAGEMENT:
  • PRESSURE MODES: 3 modes available: variable or 3 pre-set levels or 10 pre-set levels - from 100 to 900 mmHg, 50 mmHg increment LOW:- 0.4 kg/cm2 (300 mmHg), MID:-0.4 kg/cm2 (600 mmHg), HIGH:-0.4 kg/cm2 (900 mmHg), tolerance +/-20%
  • DPS: The Dynamic Pressure System - DPS - warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
  • PRESSURE MONITORING: Graphic representation of the pressure limit
  • ANTI-BOLUS SYSTEM: Reduces significantly bolus after occlusion release.

PRE-ALARMS/ ALARMS/ SECURITY:
  • PUMP STATUS: Red for AC power status and Yellow for infusion in progress. Idle/ Non operative time over. Visibility up to 5 meters. All alarms are expressed by means of flashing messages on LCD, graphics and sound beep.
  • SYRINGE POSITION CONTROL: Syringe barrel knob check, Plunger head detection, Anti-siphon system check, Flange detection.
  • DEVICE CONTROL: Disengaged driving mechanism alarm, Low battery pre-alarm, Discharged battery alarm, battery capacity, display in hours and minutes, unconfirmed programming, Technical malfunction alarm, Drive system advance check, Watchdog check, Communication
  • connection failure.
  • INFUSION CONTROL: Occlusion pressure pre-alarm, Occlusion pressure alarm, End of infusion pre-alarm, End of infusion alarm, Syringe empty, KVO, Volume limit pre-alarm, Volume limit alarm, Keypad locking, Hard and soft flow rate limits.
  • MAINTENANCE: Preventive maintenance warning..

TECHNICAL SPECIFICATIONS:
  • BATTERY: 8.4V Rechargeable Ni-Mh, Capacity minimum:10 hrs @ 5 ml/hr, Battery replacement: separate compartment – no need for electrical security testing.
  • OPERATING CONDITIONS: Temp: 05° to 40°C/ Humidity: 15 to 90 % (no condensation)/ Atmospheric Pressure: 70 to 106 kPa
  • STACKABILITY (Optional): Up to 3 devices self – stackable on a pole.
  • COMMUNICATION PORT: RS 232C
  • STANDARD ACCESSORIES: Unit with IV Pole Mounting Device, Operating Manual


Additional Information:
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: BY AIR/ON ROAD
  • Production Capacity: 500 QTY.PER MONTH
  • Delivery Time: 8-10 days
  • Packaging Details: Will pack in board boxes
Looking for Syringe Infusion Pump ?
Share Us:
© Plenum Tech Private Limited
Desktop Site Back to top